Solution
Position:Home > Solution > AMI System

Functions

Administration 

Meter Administration

Concentrator Administration

Monitoring of System Components Replacement History

Monitoring of Command and Parameter History of System Components

Defining of Roles and Users/User Groups

Access Control to System Components and AMR Centre

Administration of reporting functions of AMI Centre

Regular Automatic Backup of All Data At the Desired Time

Data Reading/Collection and Archiving

Reading of Individual Concentrator/meter

Reading of the Group of Concentrators/Meters

Automated Reading According to the Sequence

Reading On Request

Periodical Reading on Request

Special Reading on Request

Data collected automatically according to the sequence set in advance include the following

Daily Register Values

Meter States

Electricity Quality Log

Event Log

Load Profile

Hourly Register Values

State of Monthly Accounting Registers

Time and Date

Data collected from the meter on request including:

Effective Voltage Values Per Phases At the Moment of Reading

Effective Current Values Per Phases At the Moment of Reading

Current Power – (Load Power At the Moment of Reading)

Tariff Programmer

Integration Period for 15-Minute Maximum Power

Consumption Management Parameters

Parameters for Voltage Thresholds Within Electricity Quality Log

Parameters or Time Intervals of Profiles

Parameters for Registers Within Profiles

Parameters Related to the Presentation On Meter Display

Archive States of Accounting Registers

Current State of Bi-stabile Switch

Meter Software Version

Factory Number and Type of Meter

Data read according to the sequence from the concentrator including:

Statistics of Communication / Emergency and Regular Reports

Data read from the concentrator upon the request including:

Concentrator Data Archive

Reading Programmes/Sequences

Management/Parameterisation Programmes/Sequences

Programmes/Sequences Execution Priorities

Communication Routes

Concentrator Response Time and Frequency Parameters

Communication Parameters of the Concentrator

Current Date and Time

Other Concentrator Parameters

Concentrator Software Version

Records on Concentrator Parameter Changes and Adjustments

Reporting functions

Reports with Analysis of Statuses and Alarms

Reports on Electricity Quality

Reports Related to Parameterization and Management

Communication Reports

Control Reports

Reports Generated by the Concentrator

Data and Information Exchange with Other Information Systems and Subsystems of Electric Utility
Robust protocol library for various types of DCUs and electronic energy meters, DLMS/COSEM, IEC61870-5-102 compliant